Access Navigator - Release 1.8 August 2003 10-21
Provision GR-303 Service
Provision “Drop” DS1 Circuits to Subscriber
Provision “Drop” DS1 Circuits to Subscriber
1. Show drop DS1 settings with the following command:
show ds1 <n>
Example: show ds1 9
The show command will produce a message showing the DS1 settings. For example, the message
for DS1 number 1 might look similar to the following:
Settings for DS1 9:
Circuit ID: CA DS1# 9
Up/Down: DOWN
Framing: ESF
Line Coding: B8ZS
Type: DROP
Clock Source: NORMAL
Line Build Out: CSU ATTEN FOR -15dB
Loop Code Detection: ON
Loop Back: OFF
Line Termination ID: 0 (for switch DS1s only)
Remote Device MGMT: CA IP 192.168.201.1
PPHONE Call Connection: Enabled
FDL Type: None
P-Phone: In Service
Send Code: NONE
Performance Thresholds: 15 min. 1 hour 1 day
-------- ------- ------
unavailable seconds: 0 0 0
severely errored seconds: 0 0 0
errored seconds: 0 0 0
sev. errored frame seconds: 0 0 0
degraded minutes: 0 0 0
linecode violations: 0 0 0
NOTE: In the above message, loop back is a test function that is turned off during
normal service. Line Termination IDs are used only for GR-303 switch DS1s.
FDL Status does not appear if FDL Type is none.
P-Phone settings only appear in the Access Navigator / GR-303 Host with P-Phone option,
when the Remote Management type is CA IP with P-Phone enabled and the remote device
is an Adit 600. (If P-Phone isn’t enabled, the setting will list it as disabled.) (See Provision
Remote Adit 600 via IP DS0 on page 13-1.)