Access Navigator - Release 1.8 August 2003 18-109
CLI Language Reference
CLI Command List
Set DS1 ID
Purpose: Sets the carrier’s DS1 circuit identifier string.
Security: Level 2 (operator)
Syntax: set ds1 <n> id <"id">
Example: set ds1 9 id "CA ds1 #9"
Set DS1 LBO
Purpose: Sets the DS1 line buildout (lbo) to the required DSX-1 equalization or CSU
attenuation.
Security: Level 2 (operator)
Syntax: set ds1 <n> lbo <setting>
Example: set ds1 9 lbo 8
Set DS1 Line Loopup
Purpose: Provides line loopback to verify that the DS1 signal is reaching the Access Navigator’s
Quad T1 Framer card. The line loopup command creates a connection inside the Line
Interface Unit (LIU), causing it to loop the DS1 receive (input) back to the transmit
(output). See Figure 18-28.
NOTE: For normal operation, the loopback must be disabled (loopdown).
Field Description
n DS1 number, 1 to 32.
"id" A text string of up to 30 characters enclosed in quote marks.
Field Description
n DS1 number, 1 to 32, or a range of numbers such as 2-8.
setting The line buildout setting is a number, from 1 to 9.
1 – Set DSX-1 equalization for 0-133 ft.
2 – Set DSX-1 equalization for 133-266 ft.
3 – Set DSX-1 equalization for 266-399 ft.
4 – Set DSX-1 equalization for 399-533 ft.
5 – Set DSX-1 equalization for 533-666 ft.
6 – Set CSU attenuation for LBO of 0dB.
7 – Set CSU attenuation for LBO of -7.5dB.
8 – Set CSU attenuation for LBO of -15dB.
9 – Set CSU attenuation for LBO of -22.5dB.