6-14 August 2003 Access Navigator - Release 1.8
Electrical Installation
Connect DSX-1 Cables to Interface or Patch Panel
Connect DSX-1 Cables to Interface or Patch Panel
WARNING! NEBS REQUIREMENT. DO NOT CONNECT THIS EQUIPMENT DIRECTLY
TO METALLIC TIP-AND-RING OUTSIDE PLANT CONDUCTORS. THIS EQUIPMENT CAN ONLY
BE USED FOR INTRA-BUILDING (INSIDE PLANT) INSTALLATION IN A CENTRAL OFFICE OR
CUSTOMER PREMISES.
NOTE: Access Navigator can be equipped with up to 32 DS1 interfaces, in steps of 4
DS1s per Quad Framer (QF) circuit card installed. DS1 receive and transmit pairs are
numbered sequentially from 1 to 32 in Table 2-1.
NOTE: ABAM shielded cable is recommended for extending DSX-1 connections.
Connect DSX-1 receive and transmit cables to DSX-1 interface or patch panel.
Follow standard practices for DS1 signal connections.
For DSX-1 cable pin connections and flying wire colors, refer to Table 2-1.