18-52 August 2003 Access Navigator - Release 1.8
CLI Language Reference
CLI Command List
Message:
RS232:
Port type: Subrate
RTS: Not Asserted
DTR: Not Asserted
CTS: Not Asserted
CD: Not Asserted
Stop Bit: 1
Parity: none
Data Bits: 8
Baud Rate: 9600
Description:
Read Remote Performance
Purpose: Reads and displays the performance statistics of a remote Access Bank II T1 or T1
Drop at the far end of the DS1. The interval timer in the Access Bank II is only reset
by a power-on reset or reset remote command. Consequently, the performance
measurements reflect data collected during the last 0 to 15 minutes of the current 15-
minute interval.
Security: Level 3 (monitor)
Syntax: read remote <n> <t1|t1drop> performance
Item Description
Port type Subrate – asynchronous data port.
RTS Request to Send: Asserted, Not Asserted.
DTR Data Terminal Ready: Asserted, Not Asserted.
CTS Clear to Send: Asserted, Not Asserted.
CD Carrier Detect: Asserted, Not Asserted.
Baud Rate 1200, 2400, 4800, 9600, 19200, 38400, 57600
Data Bits 7, 8
Parity None, Odd, Even
Stop Bits 1, 2
Field Description
n DS1 number, 1 to 32.
t1 Read T1 performance statistics
t1drop Read T1 Drop performance statistics