Access Navigator - Release 1.8 August 2003 6-27
Electrical Installation
Alarm Output Connections
Alarm Output Connections
Installation Summary
n Precautions ... 6-27
n Tools and Materials ... 6-27
n Wire Alarm Output Connector ... 6-28
n Plug Output Alarm Connector into Access Navigator ... 6-30
Precautions
DANGER! OBSERVE EXTREME CAUTION IF FACILITY ALARM SYSTEM USES HIGH
VOLTAGE.
WARNING! DO NOT EXCEED MAXIMUM RELAY CONTACT RATINGS OF 1 AMPERE AT
110
VOLTS AC OR DC. EXCESSIVE CURRENT OR VOLTAGE WILL DAMAGE THE RELAY
CONTACTS IN THE ACCESS NAVIGATOR.
Tools and Materials
Obtain the following tools and materials:
Pliers, needle nose
Cutters, diagonal
Wire stripper, 16-26 AWG
Continuity tester
Volt-ohm meter
16 to 26 AWG insulated copper wire for alarm connections, as required by standard wiring
practices