Access Navigator - Release 1.8 August 2003 11-23
Provision Remote Access Bank II
Configure Remote RS-232 Interface (if used)
3. Set baud rate with the following command:
set remote <n> rs232 baud <setting>
Example: set remote 11 rs232 baud 9600
Available baud settings are: 1200, 2400, 4800, 9600, 19200, 38400, 57600.
4. Set number of data bits and parity with the following command:
set remote <n> rs232 data <e7|o7|n8>
Example: set remote 11 rs232 data n8
5. Set number of stop bits with the following command:
set remote <n> rs232 stop <1|2>
Example: set remote 11 rs232 stop 1