Send DS1 Line Pattern with BER Test
08:15:49 FBE:0 BE:0 CRC:0 BPV/LCV:0
08:15:50 FBE:0 BE:0 CRC:0 BPV/LCV:0
08:15:51 FBE:0 BE:0 CRC:0 BPV/LCV:0
08:15:52 FBE:0 BE:0 CRC:0 BPV/LCV:0
08:15:53 FBE:0 BE:0 CRC:0 BPV/LCV:0
08:15:54 FBE:0 BE:0 CRC:0 BPV/LCV:0
08:15:55 FBE:0 BE:0 CRC:0 BPV/LCV:0
08:15:56 FBE:0 BE:0 CRC:0 BPV/LCV:0
Totals Error Rates
FBE: 0 0.000000e+00
BE: 0 0.000000e+00
CRC: 0 0.000000e+00
LCV/BPV: 0 0.000000e+00
Signaling done.
The following error message will occur if an incorrect pattern is received:
Message: Waiting for pattern sync.........no sync.
The following error message will occur if there is no loopback in effect:
Message: *-Unable to send code;
*- far-end is not in loopback.
Description:
Item Description
Time Time is recorded in one-second intervals. Format is 24-hour
clock in hours:minutes:seconds with colons to separate the digits,
as in 08:30:45 and 15:22:10.
FBE Number of Frame Bit Errors (4095 maximum) in one-second
interval.
BE Number of Bit Errors (4095 maximum) in one-second interval
CRC Number of Cyclical Redundancy Check errors (1023 maximum)
in one-second interval
BPV/LCV Number of Bi-Polar Violations and Line Code Violations
(16,383 maximum) in one-second interval
Totals Total number of errors for 10-second test interval
Error Rates Total error rates measured during the 10-second test interval,
expressed in scientific notation where "e" indicates a power of
10. For example, 1 error per 1.544 megabits is 6.520000e-07.
The maximum value is 2.700000e-03.