EasyManua.ls Logo

Carrier Access Access Navigator - Page 525

Carrier Access Access Navigator
704 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Access Navigator - Release 1.8 August 2003 18-69
CLI Language Reference
CLI Command List
Message: Waiting for pattern sync........ok.
Testing line...
08:15:47 FBE:0 BE:0 CRC:0 BPV/LCV:0
08:15:48 FBE:0 BE:0 CRC:0 BPV/LCV:0
08:15:49 FBE:0 BE:0 CRC:0 BPV/LCV:0
08:15:50 FBE:0 BE:0 CRC:0 BPV/LCV:0
08:15:51 FBE:0 BE:0 CRC:0 BPV/LCV:0
08:15:52 FBE:0 BE:0 CRC:0 BPV/LCV:0
08:15:53 FBE:0 BE:0 CRC:0 BPV/LCV:0
08:15:54 FBE:0 BE:0 CRC:0 BPV/LCV:0
08:15:55 FBE:0 BE:0 CRC:0 BPV/LCV:0
08:15:56 FBE:0 BE:0 CRC:0 BPV/LCV:0
Totals Error Rates
FBE: 0 0.000000e+00
BE: 0 0.000000e+00
CRC: 0 0.000000e+00
LCV/BPV: 0 0.000000e+00
Signaling done.
The following error message will occur if an incorrect pattern is received:
Message: Waiting for pattern sync.........no sync.
The following error message will occur if there is no loopback in effect:
Message: *-Unable to send code;
*- far-end is not in loopback.
Description:
Item Description
Time Time is recorded in one-second intervals. Format is 24-hour
clock in hours:minutes:seconds with colons to separate the digits,
as in 08:30:45 and 15:22:10.
FBE Number of Frame Bit Errors (4095 maximum) in one-second
interval.
BE Number of Bit Errors (4095 maximum) in one-second interval
CRC Number of Cyclical Redundancy Check errors (1023 maximum)
in one-second interval
BPV/LCV Number of Bi-Polar Violations and Line Code Violations
(16,383 maximum) in one-second interval
Totals Total number of errors for 10-second test interval

Table of Contents