Access Navigator - Release 1.8 August 2003 18-141
CLI Language Reference
CLI Command List
Message:
Settings for DS1 9:
Circuit ID: CA DS1# 9
Up/Down: DOWN
Framing: ESF
Line Coding: B8ZS
Type: DROP
Clock Source: NORMAL
Line Build Out: CSU ATTEN FOR -15dB
Loop Code Detection: ON
Loop Back: OFF
Line Termination ID: 0 (for switch DS1s only)
Remote Device MGMT: CA IP 192.168.201.1
PPHONE Call Connection: Enabled
FDL Type: None
Send Code: NONE
Performance Thresholds: 15 min. 1 hour 1 day
-------- ------- ------
unavailable seconds: 0 0 0
severely errored seconds: 0 0 0
errored seconds: 0 0 0
sev. errored frame seconds: 0 0 0
degraded minutes: 0 0 0
linecode violations: 0 0 0
NOTE: The Performance Thresholds are threshold values, not error counts.
Description:
Item Description
Circuit ID Circuit identifier set by user for the DS1 number.
Up/Down Link service status: UP, DOWN.
Framing D4 (SF), ESF, SLC96 (S4).
Line Coding AMI, B8ZS.
Type DROP, GROOM, SWITCH. Switch type appears only with GR-
303 option.
Clock Source NORMAL, LOOP.
Line Build Out DSX-1 equalization (ft.), CSU attenuation (dB).
Loop Code Detection ON, OFF.
Loop Back OFF, LINE, PAYLOAD.
Line Termination ID Line termination identifier, 1 to 28, set by user (used by GR-303
only.
Remote Device MGMT NONE, CAFDL, CAIP <ipaddress>, DS1 <n>.

Table of Contents