3-CONTROLSANDINSTRUMENTS
OUTPUTREDUCTIONCANCEL
TheOUTPUTREDUCTIONCANCELfunctionallowstotemporarilyoverridetheenginederatingconditioninthestep
Coftheinducementsequence.
Thefunctionoverridestheenginederatefor30minmaximum,andismainlyintendedtoaddressdangeroussitua-
tions.
ToactivatetheOUTPUTREDUCTIONCANCELfunction,accesstheuserinformationmodeofthedisplayandselect
theSCRCONFIGURATIONtab:setOUTPUTREDUCTIONCANCELtoON.
NOTICE:TheOUTPUTREDUCTIONCANCELfunctioncannotbeactivatedinthestepDoftheinducementse-
quence.
Resumingtheoperatingmodeofthedisplay,theESCAPEMODEwarningandthemessageOUTPUTREDUCTION
CANCELEDaredisplayed.
SMIL16CEX1377EA13
Operatethemachineinordertoreachasafeconditionwithin30min.Stoptheengine,andmakesuretotakethe
appropriateactionrequiredbytheinducementsequence,asforexamplerellingDEF/AdBlue®orrepairingtheSCR
system.
Iftheoperationiscontinuedformorethan30min,theengineisderatedagain,andthestepCoftheinducement
sequenceisrestored.