6-MAINTENANCE
Fueltankdrain
WARNING
Firehazard!
Whenhandlingdieselfuel,observethefollowingprecautions:
1.Donotsmoke.
2.Neverllthetankwhentheengineisrunning.
3.Wipeupspilledfuelimmediately.
Failuretocomplycouldresultindeathorseriousinjury.
W0099A
Drainwaterandsedimentfromthefueltankevery10horeveryday
NOTE:Takeallnecessaryprecautionsduringthefollowingoperations;noforeignmattermustenterthefuelsystem.
1.Placeareceptacleofasuitablecapacityunderthe
drainplug.
2.Openthedrainvalvelocatedatthebottomofthetank
anddraintheaccumulatedsedimentandwater.
3.Afterdraining,closethedrainvalve.
SMIL17CEX3273AA1
6-20