6-MAINTENANCE
Fuellter
WARNING
Firehazard!
Whenhandlingdieselfuel,observethefollowingprecautions:
1.Donotsmoke.
2.Neverllthetankwhentheengineisrunning.
3.Wipeupspilledfuelimmediately.
Failuretocomplycouldresultindeathorseriousinjury.
W0099A
Replacethefuellterelementevery500h
NOTICE:Donotworkinanyenvironmentinwhichanythingotherthanfuelwillgetintofuellines.(Siteswithstrong
wind,blowingdust,etc.).Washhandsbeforeoperations.Donotusegloves.Donotopenthepackagingforthelter
kituntilyoustarttheinstallationwork.Donotreuseanyfuelremainingwithinthecover.Forpersistentdirtwithinthe
cover,wipeitoffwithacleanrag,thencleanwithcleandieselfuel.Donotusepartscleanerbecauseitcouldaffect
thecasecover.Donottouchtheinsideoftheelement.Completelywipeoffanyspilledfuelafterchangingthelter
element.
NOTE:IfusingafuellterotherthantheCASECON-
STRUCTIONgenuinelter,youwillnolongerbeguaran-
teedagainstthetroublecausedbyuseofthewronglter.
Takethesameprocedureasthatforthepre-lter.
NOTE:Tighteningtorqueofthemainunitis28–32N·m
(20.65–23.60lbft).
SMIL17CEX3534AA1
Bleedthefuelsystem.Refertopage6-11.
6-43