Environmental Specifications
ASR 5000 Installation Guide
282
Operating and Storage Parameters
Use the following information to plan your network installation for the ASR 5000 platform.
Table 106. Temperature, Humidity and Altitude Recommendations
Temperature
Operating
0 degrees C to +55 degrees C
Storage
-40 degrees C to +70 degrees C
Humidity
Operating
20 to 80 percent non-condensing
Storage
10 to 95 percent non-condensing
Altitude
Operating
197 ft. (60m) below to 13,123 ft. (4,000m) above sea level
Non-operating
197 ft. (60m) below to 49,212 ft. (15,000m) above sea level
Supported Environmental Standards
The system has been successfully tested against the following environmental standards:
Operational Thermal, Operating Conditions - GR-63 Criteria [72, 73]
Airborne Contaminants, Indoor Levels - GR-63 Criterion [125]
Operational Thermal, Short-term Conditions - GR-63 Criteria [72, 73]
Storage Environments, and Transportation and Handling - GR-63 Criteria [69-71, 107-109, 124]
Earthquake Zone 4 - GR-63 Criteria [110-112, 114, 115, 117, 119]
Airborne Contaminants, Outdoor Levels - GR-63 Criteria [126, 127]
Altitude - GR-63 Criteria [74, 76]
Thermal Heat Dissipation - GR-63 Criteria [77-79]
Acoustic Noise - GR-63 Criterion [128]
ESTI 300 019 - Environmental conditions and environmental tests for telecommunications equipment