Chassis Installation
Installing the Chassis
ASR 5000 Installation Guide
79
Re-Installing Chassis Sub-components
If you performed the procedure in the Reducing the Weight of the Chassis Prior to Installation section, complete the
procedures described below to re-install the sub-components of the chassis.
Caution: During installation, maintenance, and/or removal, wear grounding wrist straps to avoid ESD damage
to the components. Failure to do so could result in damage to sensitive electronic components and potentially void your
warranty.
Step 1 Re-install the PFUs into the chassis.
Step a Locate the PFU bays at the lower-rear of the chassis. The bays are labeled from left to right Power
Filter Unit 1 and Power Filter Unit 2.
Step b Slide the PFU assembly into the PFU bay labeled Power Filter Unit 1 until it is flush against the
chassis.