Citrix SD-WAN Platforms
Specifications 4100 WANOP 5100 WANOP
Number of power supplies 2 power supplies providing
full hot swap redundancy
2 power supplies providing
full hot swap redundancy
AC power supply 100–240 V ac, 50 Hz to 60 Hz,
2 x 9.0 to 4.5A
100–240 V ac, 50 Hz to 60 Hz,
2 x 9.0 to 4.5A
DC power supply -36 V dc to -72 V dc, 2 x 25.5 to
13.0A
-36 V dc to -72 V dc, 2 x 25.5 to
13.0A
Maximum AC power
consumption
633 W 822 W
Maximum DC power
consumption
712 W 895 W
Airflow (front to rear) 65 CFM, typical 65 CFM, typical
Heat Dissipation 137 W/FT 2/FT, typical 144 W/FT 2/FT, typical
Package weight (lbs.)
Shipping dimensions and
weight
62 lbs (28.1 kgs) 64 lbs (29.10 kgs)
Dimensions 36.5” x 24.5” by 11” (93 cm x
63 cm x 28 cm)
36.5” x 24.5” by 11” (93 cm x
63 cm x 28 cm)
System weight (lbs.) 45 lbs (20.4 kg) 47 lbs (27 kg)
Rack Units 2U 2U
Width EIA 310-D, IEC 60297, DIN
41494 SC48D rack 17.25” (44
cm)
EIA 310-D, IEC 60297, DIN
41494 SC48D rack 17.25” (44
cm)
Depth 28“ (71.1 cm) 28“ (71.1 cm)
Operating temperature 32–104 F (0–40 C) 32–104 F (0–40 C)
Non-operating temperature 14F to 140F (-10C to 60C) 14F to 140F (-10C to 60C)
Humidity range
(non-condensing)
5%-95% non-condensing 5%-95% non-condensing
Safety certifications IEC 60950-1, second Edition;
CSA 60950-1, second Edition;
UL 60950-1, second Edition;
AS/NZS 6050-1
IEC 60950-1, second Edition;
CSA 60950-1, second Edition;
UL 60950-1, second Edition;
AS/NZS 6050-1
© 1999-2021 Citrix Systems, Inc. All rights reserved. 38