Citrix SD-WAN Platforms
• Non-maskable interrupt (NMI) button, for use at the request of Technical Support to produce a
core dump. Use a pen, pencil, or other pointed object to press this red button, which is recessed
to prevent unintentional activation.
• Single power supply, rated at 300 watts, 100–240 volts.
Citrix SD-WAN 1000 PE (EE) Appliance
June 19, 2020
The SD-WAN 1000 PE (EE) platform has a quad-core processor and 32 GB of memory. This platform
has a bandwidth of up to 100 Mbps.
The following figure shows the front panel of an SD-WAN 1000 PE (EE) appliance.
Figure 1. Citrix SD-WAN 1000 PE (EE), front panel
• The front panel of the SD-WAN 1000 PE (EE) appliance has a power button and five LEDs.
• The power button is used to switch the appliance on or o.
• The reset button restarts the appliance.
The LEDs provide critical information related to dierent parts of the appliance.
• Power Fail – Indicates the power supply unit has failed.
• Information LED – Indicates the following:
Status Description
Continuously ON and red The appliance is overheated.
Slow blink - 1 blink per second Fan failure, check for an inoperative fan.
Fast blink - 4 blinks per second Power failure, check for the non-operational
power supply.
Solid blue Local UID has been activated. Use this function
to locate the server in a rack mount
environment.
© 1999-2021 Citrix Systems, Inc. All rights reserved. 123