188 678.1 - RHB LEXION 480 5.2.3
Grain elevator
Removing the clean grain elevator head
Remove the grain elevator chain.
Release the tension of the grain tank filler auger drive
chain (K) and remove chain.
(Fig. 7)
Remove the chain adjusting straps (L) from their
mounting plate.
(Fig. 8)
Unbolt the elevator head from the main housing and
remove by lifting it off.
(Fig. 9)