188 678.1 - RHB LEXION 480 9.5.17
Hydraulic cylinders – High-pressure hydraulic circuit
Assembling the rotary coupling
Insert the O-ring (15), the seal (12) and the stepped
washer (13) into the adapter (10) and secure with
circlip (14).
Observe installation position of seal (12) and stepped
washer (13).
(Fig.40,41,42)
When installing the back-up ring (11) and the stop
washer (9) into the adapter (10), observe correct
installation position.
(Fig. 41, 43)
41
42
43