188 678.1 - RHB LEXION 480 5.3.7
Grain tank unloading
7.
Installing and adjusting the grain tank unloading
drive chain (17)
, see page 7.2.35
8. Bolt on the conical graduation plates (13) above
the horizontal cross augers, ensuring that the top
edges will touch each other.
(Fig. 10, 19)
Removing the vertical grain tank unloading
auger
Remove the drive wheel and the mud guard (K) on the
left-hand side of the machine.
(Fig. 20)
From serial no. …:
Release the tension of the grain tank unloading drive
chain and remove chain – see page 7.2.34,
Removing
the grain tank unloading drive chain (17)
.
Measure the clearance between shaft end and
sprocket.
(Fig. 21)
From serial no. …:
Remove gib head key using a key extractor.
(Fig. 22)
19
20
21