65 | R-net Technical Manual | Chapter 3 Programming
Inhibit Type For parameter information - Refer to the Chapter ISM8
Inputs ASM/TM
Lower Level Threshold For parameter information - Refer to the Chapter ASM/TM
Middle Level Threshold For parameter information - Refer to the Chapter ASM/TM
Upper Level Threshold For parameter information - Refer to the Chapter ASM/TM
Debounce Time Inh For parameter information - Refer to the Chapter ASM/TM
Drive Inhibits
Assign Links the software inhibits to an actual hardware inhibit
Speed Limit in Band 0 Sets the max speed when the Inhibit Input, which is assigned to the Drive Inhibit, is in Band 0
Speed Limit in Band 1 Sets the max speed when the Inhibit Input, which is ass igned to the Drive Inhibit, is in Band 1
Speed Limit in Band 2 Sets the max speed when the Inhibit Input, which is assigned to the Drive Inhibit, is in Band 2
Speed Limit in Band 3 Sets the max speed when the Inhibit Input, which is assigned to the Drive Inhibit, is in Band 3
Operation Sets whether a full drive inhibit is a latching or non-latching function
Inhibit Alarm Sets whether an audible alarm will sound in a full drive inhibit condition
Actuator Channel ‘x’ Inhibits
Up: Assign Links the software inhibits to an actual hardware inhibit
Up: Inhibit in Bands Sets the condition of the input that will result in an inhibit of an actuator channel in the up direction
Up: Alarm Sets whether an audible alarm will sound when an actuator channel is inhibited in the up direction
Down: Assign Links the software inhibits to an actual hardware inhibit
Down: Inhibit in Bands Sets the condition of the input that will result in an inhibit of an actuator channel in the down direction
Down: Alarm Sets whether an audible alarm will sound when an actuator channel is inhibited in the down direction
Actuator Channel ‘x’ Inhibits ISM8/CxSM
Up: Assign For parameter information - Refer to the Chapter ISM8
Up: Inhibit in Bands For parameter information - Refer to the Chapter ISM8
Up: Alarm For parameter information - Refer to the Chapter ISM8
Down: Assign For parameter information - Refer to the Chapter ISM8
Down: Inhibit in Bands For parameter information - Refer to the Chapter ISM8
Down: Alarm For parameter information - Refer to the Chapter ISM8
Lights
Global
Indicator Fault Detection Sets whether defective turn indicator lamps can be detected
Swap Indicators Seat Reversal Sets whether the indicator channels are exchanged when the seat is reversed
Intelligent Seating Module
Lamp Voltage Sets the operating voltage for the wheelchair’s lighting system
Brake Lights or Horn Sets whether the spare outputs on the ISM are assigned as Brake Lights or Horn
Indicator Fault Detection 15V Sets whether defective LED turn indicator lamps can be detected at 15V
Indicator Fault Detection 20V Sets whether defective LED turn indicator lamps can be detected at 20V
Indicator Fault Detection 25V Sets whether defective LED turn indicator lamps can be detected at 25V
Indicator Fault Detection 30V Sets whether defective LED turn indicator lamps can be detected at 30V
Indicator Fault Detection 35V Sets whether defective LED turn indicator lamps can be detected at 35VDigitmal
Lighting Module
Lamp Voltage For parameter information - Refer to the Chapter Lighting Module
Light Power For parameter information - Refer to the Chapter Lighting Module
Indicator Power For parameter information - Refer to the Chapter Lighting Module
Indicator Fault Power For parameter information - Refer to the Chapter Lighting Module
OEM Factory
Absolute Max Torque Sets the maximum programmable value
Absolute Minimum Power Sets the minimum programmable value
Absolute Maximum Forward Speed Sets the maximum programmable value
Absolute Minimum Forward Speed Sets the minimum programmable value
Absolute Maximum Reverse Speed Sets the maximum programmable value
Absolute Minimum Reverse Speed Sets the minimum programmable value
Absolute Maximum Turning Speed Sets the maximum programmable value
Absolute Minimum Turning Speed Sets the minimum programmable value
Absolute Maximum Forward Acceleration Sets the maximum programmable value