References
274
PowerScan™ PD9330/PBT9300/PM9300
Table 42
STEP ACTION EXAMPLES
1.
Scan the ENTER/EXIT bar
code
(Scanner enters Programming Mode)
2.
Determine placement of
the
Label ID characters
BEFORE or AFTER with
regard to scanned data
using
Label ID
Control, starting on page
55
Enable as Prefix Enable as Suffix Enable as Prefix Enable as Suffix
3.
Scan the bar code selecting
the
symbology type you
wish to designate label ID
characters for using
Label
ID Symbology
Selection, starting on
page 56
.
DataBar
Omnidirectional
Code 39
Interleaved 2 of
5
Code 32
4.
Custom Label ID example
(desired characters):
D B * = C 3 + P H
5.
Find hex equivalents from
the
ASCII Chart(inside
back cover), then scan in
the
se digits/characters
using the bar codes in the
section:
Keypad, starting
on page 313
. If you make
a mistake before the last
character, scan the CANCEL
bar code to abort and not
save the entry string. You
can then start again at the
beginning.
44 42 2A 3D 43 33 2B 50 48
6.
Scan the ENTER/EXIT bar
code
(Scanner exits Label ID entry)
7.
Scan the ENTER/EXIT bar
code once
again
(Scanner exits Programming Mode)
Result:
DB*[bar code
data]
[bar code
data]=C3
+[bar code data] [bar code data]PH
. Label ID Examples

Table of Contents

Other manuals for Datalogic PD9330

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic PD9330 and is the answer not in the manual?

Datalogic PD9330 Specifications

General IconGeneral
BrandDatalogic
ModelPD9330
CategoryBarcode Reader
LanguageEnglish

Related product manuals