1) Button to go to the alarm page. In the presence of an active alarm the colour of the
triangle button is yellow.
2) ON / OFF of the gusseting. Green button = ON, Gray button = OFF.
3) ON/OFF button for the blowing device for double product removal.
4) Button to return to the previous page.
5) Button to close this page.
6) Visualization of the position of the jaws, in cam degrees.
7) Button to set the start position of the gusseting, in cam degrees.
8) Button to set the duration of the gusseting.
9) Button to set the duration of the blowing device for double product removal.
To enter the desired value, proceed as follows:
• Press the green key of interest.
• A numeric keypad appears, type the desired data.
• Confirm with Enter.