Virtual Private Networks (VPN) IPsec
Digi Connect IT® 4 User Guide
344
l Override wait interval before performing the next recovery action: The
time to wait before the next test is run. If set to the default value of 0s, the Test
interval is used.
n Switch to alternate SIM: Switches to an alternate SIM. This recovery action is
available for WWANinterfaces only.
If Switch to alternate SIM is selected, complete the following:
l Attempts: The number of attempts for this recovery action to perform, before
moving to the next recovery action.
l Override wait interval before performing the next recovery action: The
time to wait before the next test is run. If set to the default value of 0s, the Test
interval is used.
n Reboot device.
If Reboot device is selected, complete the following:
l Attempts: The number of attempts for this recovery action to perform, before
moving to the next recovery action.
l Override wait interval before performing the next recovery action: The
time to wait before the next test is run. If set to the default value of 0s, the Test
interval is used.
n Execute custom Recovery commands.
If Recovery commands is selected, complete the following:
l Attempts: The number of attempts for this recovery action to perform, before
moving to the next recovery action.
l The Commands to run to recovery connectivity.
l Override wait interval before performing the next recovery action: The
time to wait before the next test is run. If set to the default value of 0s, the Test
interval is used.
n Powercycle the modem. This recovery action is available for WWANinterfaces only.
If Powercycle the modem is selected, complete the following:
l Attempts: The number of attempts for this recovery action to perform, before
moving to the next recovery action.
l Override wait interval before performing the next recovery action: The
time to wait before the next test is run. If set to the default value of 0s, the Test
interval is used.
f. Repeat for each additional recovery action.
13. (Optional) Configure advanced SureLink parameters:
a. Click to expand Advanced settings.
b. For Delayed Start, type the amount of time to wait while the device is starting before
SureLink testing begins. This setting is bypassed when the interface is determined to be
up.
Allowed values are any number of weeks, days, hours, minutes, or seconds, and take the
format number{w|d|h|m|s}.
For example, to set Delayed start to ten minutes, enter 10m or 600s.