EasyManuals Logo

Digi Connect IT 4 User Manual

Digi Connect IT 4
964 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #66 background imageLoading...
Page #66 background image
Interfaces Wide Area Networks (WANs)
Digi Connect IT® 4 User Guide
66
n Reboot device.
If Reboot device is selected, complete the following:
l Attempts: The number of attempts for this recovery action to perform, before
moving to the next recovery action.
l Override wait interval before performing the next recovery action: The
time to wait before the next test is run. If set to the default value of 0s, the Test
interval is used.
n Execute custom Recovery commands.
If Recovery commands is selected, complete the following:
l Attempts: The number of attempts for this recovery action to perform, before
moving to the next recovery action.
l The Commands to run to recovery connectivity.
l Override wait interval before performing the next recovery action: The
time to wait before the next test is run. If set to the default value of 0s, the Test
interval is used.
n Powercycle the modem. This recovery action is available for WWANinterfaces only.
If Powercycle the modem is selected, complete the following:
l Attempts: The number of attempts for this recovery action to perform, before
moving to the next recovery action.
l Override wait interval before performing the next recovery action: The
time to wait before the next test is run. If set to the default value of 0s, the Test
interval is used.
f. Repeat for each additional recovery action.
12. (Optional) Configure advanced SureLink parameters:
a. Click to expand Advanced settings.
b. For Delayed Start, type the amount of time to wait while the device is starting before
SureLink testing begins. This setting is bypassed when the interface is determined to be
up.
Allowed values are any number of weeks, days, hours, minutes, or seconds, and take the
format number{w|d|h|m|s}.
For example, to set Delayed start to ten minutes, enter 10m or 600s.
The default is 300 seconds.
c. For Backoff interval, type the time to add to the test interval when restarting the list of
actions. This option is capped at 15 minutes.
Allowed values are any number of weeks, days, hours, minutes, or seconds, and take the
format number{w|d|h|m|s}.
For example, to set Backoff interval to ten minutes, enter 10m or 600s.
The default is 300 seconds.
d. Test interface gateway by pinging is used by the Interface gateway Ping test as the
endpoint for traceroute to use to determine the interface gateway. The default is 8.8.8.8,
and should only be changed if this IP address is not accessible due to networking issues.
13. Click Apply to save the configuration and apply the change.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Digi Connect IT 4 and is the answer not in the manual?

Digi Connect IT 4 Specifications

General IconGeneral
BrandDigi
ModelConnect IT 4
CategoryNetwork Router
LanguageEnglish

Related product manuals