Operating Instructions 650-10 - 03.0 - 08/2016140
1055 Error Sewing motor overload (I²T):
Sewing motor not moving
fr
eely or blocked
Sewing motor defective
Controller defective
Remove the cause of the
stif
f movement or blockage
Replace the sewing motor
Replace the control
1056 Error Sewing motor
overtemper
ature:
Sewing motor not moving
fr
eely
Sewing motor defective
Controller defective
Correct the cause of not
moving fr
eely
Replace the sewing motor
Replace the control
1058 Error Sewing motor speed greater
than setpoint:
Reference switch defective
Sewing motor defective
Replace the reference
swi
tch
Replace the sewing motor
1060 Error PowerParts Replace the control
1061 Error Sewing motor disturbance:
Encoder defective
Sewing motor defective
Switch the machine off and
on again
Replace the encoder
Replace the sewing motor
Contact customer service
1062 Error Sewing motor disturbance
(IDMA au
to increment)
Switch the machine off and
on again
1120 Error Software error:
Parameter not initialized
Perform a software update
1203 Information Sewing motor:
Position not reached
Switch the machine off and
on again
Perform a software update
Contact customer service
1302 Error Sewing motor current error:
Sewing motor blocked
Encoder cable not
connected or defective
Encoder defective
Remove the blockage
Check the encoder cable
and rep
lace, if necessary
Replace the sewing motor
1330 Error Sewing motor not responding Switch the machine off and
on again
Perform a software update
Contact customer service
Code Type Possible causes Remedial action