Service settings via software (OP3000)
Operating Instructions 650-10 - 03.0 - 08/2016 49
The following table lists the functions that can be performed in the 
course of the seam.
5.4.2 Cancel sewing program
1. Press the Pedal fully back.
 Th
e thread is cut.
2. Press the ESC key
.
 Th
e sewing program is canceled.
Key/Pedal Function
Plus/minus 
and 
0 – 16
Temporary correction of the fullness value
(valid only for the current step)
Additional 
pedal 
(optional)
Temporary correction of the fullness value or 
the curve support (depending on the setting in the 
technician level)
(valid only for the current step)
Knee lever Next program step
/
3
Stop forward/back or to the start of the step
Switch the sleeve side (if programmed) in the 1
st
 step 
at the start of the step
/
Correction of the thread tension
The value is saved
P, F, S, OK No function assigned
Press the 
Pedal halfway 
back
Lift sewing foot
Press the 
Pedal fully 
back
Cut thread
The program remains stopped at the cutoff point 
(does NOT apply to the last step)
Lower softkey Softkey menu  
( p. 41)