Operation
Operating Instructions 650-10 - 03.0 - 08/2016 21
4.3 Changing the needle
Fig. 3: Changing the needle
Change the needle as follows:
1. Loosen the screw (2) and remove the needle.
2
. Insert the new needle into the hole in the needle bar (1) until
it reaches the end stop.
Important
The groove (4) must face towards the hook tip (3).
3. Tighten the screw (2).
CAUTION
Risk of injury from sharp parts!
Punctures possible.
Switch off the machine before changing the
n
eedle.
(1) - Needle bar
(2) - Screw
(3) - Hook tip
(4) - Groove