Service settings via software (OP3000)
Operating Instructions 650-10 - 03.0 - 08/2016 41
5.3 Manual mode
Fig. 17: Manual mode
The following table shows the individual symbols (parameters) on 
the display and the functions of the keys on the control panel. 
When a parameter is selected, its color on the display changes. 
When a parameter is changed, its new value is loaded immedia-
tely.
Symbol Meaning
(depending on the assignment)
Quick programming
• Press the upper softkey ( p. 50)
Quick access function (softkey menu)
• Press the lower softkey ( p. 42)
Program number
Value range: 000 – 999 
Program 000 indicates that the controller is in "Manual 
mode".
•Use 
/ to select the parameter
•Use 
/ to change the program number.
Or:
• Input the program number directly using one of the 
numeric keys  
0 – 9 and confirm with  OK as required
 The controller switches to Automatic mode
Fullness
Value range: Upper fullness: 0  –  16 
                       Lower fullness: 0  –  6
• Use the numeric keys 0 – 16 to select the desired 
fullness 
• Use the plus/minus key to select upper or lower 
fullness 
Or:
• Use the additional pedal to select the fullness, if fitted