Settings via software (OP7000)
Operating Instructions 650-10 - 03.0 - 08/201676
 The length in mm sewn in the seam is displayed. 
When the thread is cut, the display is reset.
You can also change parameters while in the middle of a seam.
This is how you change parameters in the middle of a seam:
1. Press Pedal to position 0.
2. Change the desired parameter on the control 
pa
nel ( p. 72).
3. Press the pedal forwards again and sew.
 Th
e seam will be sewn using the altered parameter value.
6.4 Automatic mode AUTO
Fig. 47: Automatic mode AUTO
Header (1)
The AUTO operating mode is displayed. The buttons + F% and 
- F% offer quick access for setting the fullness values in %.
(1) - Header