Troubleshooting
Operating Instructions 650-10 - 03.0 - 08/2016 145
2262 Error Y-axis stepper motor
disturbance (IDMA auto
incre
ment)
Switch the machine off and
on again
2271 Error Watchdog Switch the machine off and
on again
Perform a software update
Contact customer service
2272 Error Stepper motor overvoltage:
Stepper motor card
def
ective
Replace the control
2273 Error Y-axis stepper motor error Check the connection
Test stepper motor phases
(R = 2.8, high impedance
to PE)
Replace the encoder
Replace the stepper motor
Replace the control
2274 Error Software error Perform reset
Perform a software update
Contact customer service
2275 Error Magnet wheel search Check the connection
Test stepper motor phases
(R = 2.8, high impedance
to PE)
Replace the encoder
Replace the stepper motor
Replace the control
2277 Error Stepper motor overload (I²T) Remove the cause of the
stif
f movement or blockage
Replace the stepper motor
Replace the control
2278 Error Encoder error Check the connection of
the encoder cable and
replace
, if necessary
Replace the control
2279 Error Current sensor:
Stepper motor card
def
ective
Controller defective
Replace the control
Code Type Possible causes Remedial action