Service settings via software (OP3000)
Operating Instructions 650-10 - 03.0 - 08/2016 63
Fig. 41: Update machine software
(1) - Control
(2) -  USB key
(3) -  USB-Port
(4) -  LEDs
This is how you perform the software update:
1. Download the machine-specific update from the Dürkopp
Adler website (https://software.duerkopp-adler.com/maschi-
nenprogramme.html).
 Th
e program is packed in a .zip-file, the name con
sists of
the part number of the program, the software version and
the date, i. e. 9899_080600_000_A01.0.4_2013-12-10.zip
2. Unpack the .zip-file on a Dürkopp Adler USB key (part number 
983
5 301003).
 The update file has the ending .dacimg. 
3. Insert the USB key (2) in the USB port (3) at the control (1).
4. Switch on the machine.
 Th
e update starts. The LEDs (4) light up.
 The update is finished when only the POWER LED glows.
Import
ant
5. Calibrate the electronic thread tension ( Service Instruc-
tions).
 The m
achine is ready to sew.