Settings via software (OP7000)
Operating Instructions 650-10 - 03.0 - 08/2016 87
To set a parameter:
1. Tap the desired button.
Th
e user interface for setting the desired parameter is
displayed.
For some parameters the setting is more
than just a numerical
value. These more complex parameters are described in detail
below.
Set the fullness in the current sewing step,
p. 98
Set the curve support in the current sewing
step
Set the needle thread tension in the current
sewing step
Set the stitch length in mm in the current
sewing step
Switch the seam length measurement in
the current sewing step on or off
Other sewing step parameters in operating
mode EDIT, p. 91