1.4.3 Status information during start of firmware
The firmware is started after booting. The following indications are made in this phase.
Tab elle 9:
Table 9: 7-segment indicator, Status information during start of the firmware, ENC66
7-segment indicator Meaning
0 Initialization of processor
1 Initialization of software
2 Initialization of operating software
3 Initialization of task and mailbox
4 Initialization of I2C hardware
5 Initialization of file system
6 Initialization of local bus
7 Hardware check
Flashing light of segment Normal state acc. to description in /A/
Continuous error number Error state acc. to tables in chapter 1.4.6.1