Meaning:
F...: Fatal
E...: Error
H…: Note
F005 SYS / Initialization error during timer initialization
F101 ZST / System initialization (tasks) failed
F102 ZST / System initialization (ports) failed
F103 ZST / Error during initialization ZST task
F201 UTI / Error during initialization Monitor task
F301 PLC / Error during initialization PLC task stage 1
F302 PLC / Error during initialization PLC task stage 2
F303 PLC / Recursive PLC_PRG call
F701 MISC / Error during initialization LPDMA task
F702 MISC / Error during initialization NET task
F703 LBM / Initialisation of the LocalBus-Task failed
H202 UTI / Battery for CMOS and RTC buffering running out (warning repeated in 10-
sec. interval)
E88xx-
yyyyyyyy-
zzzzzzzz
Processor exception xx (hex) to address yyyyyyyy (hex) at stackpointer zzzzzzzz
(hex)
7-segment
indicator
Meaning
Table 13: Error indication in normal operation, ENC66