EasyManua.ls Logo

ECKELMANN UA 400 - Menu 3 Clock UA 111

ECKELMANN UA 400
401 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Firmware V3.15
21.04.2021
155/401
9.1.4 Menu 3 Clock UA 111
CLOCK POS: XXXXX Entry
1 Current Time Move to menu 3-1 1
2 Defrost timer Move to menu 3-2 2
3 Toggle Setpoints Move to menu 3-3 3
Menu 3-1 Current Time
CLOCK POS: XXXXX Entry Default
Date: XX dd.mm.yy Display and enter current weekday, date dd.mm.yy
Time: hh.mm Display and enter current time hh.mm
Daylight Saving X Display and enter automatic daylight saving
change (Y/N)
, ,(Y/N)
J
Menu3-2Defrosttimer
DERF. TIMER POS: XXXXX Entry Default
Defrost timer XXX Defrost initiation via input D11/12 ( EXT) or
internal (INT)
, ,(EXT,INT)
INT
Safe Defr Time XXX m Safe defrost time for maximum allowed
duration of defrosting (used only for internal
defrosting)
0..120 60 min
Manual Defrost XXX Status (OFF/ON) for supplementary manual
defrosting *) shown only when parameter
defrost timer = INT
, ,(ON/OFF)
OFF
Def.Tim.Z2 Separate defrost timer for zone 2 Menu 3-2-a
Defr. 1 xxxxx hh:mm Defrost start time with internal defrosting;
Weekday, time; shown only when parameter
defrost timer = INT
, , (Mo-Su etc.) or
numbers (hh:mm)
Mo-Su01:00
Defr. 2 xxxxx hh:mm Defrost start time with internal defrosting;
Weekday, time; shown only when parameter
defrost timer = INT
, ,(Mo-Suetc.)or
numbers (hh:mm)
Mo-Su07:00
Defr. 3 xxxxx hh:mm Defrost start time with internal defrosting;
Weekday, time; shown only when parameter
defrost timer = INT
, ,(Mo-Suetc.)or
numbers (hh:mm)
Mo-Su13:00
Time is defined by time master (system centre / store computer / operator terminal) when CAN bus is
connected. Any entry made will then be overwritten by the defined value.

Table of Contents