Menu 6-2-5 Sensor Type
Selectbetweenvalues.Checkmarkshowscurrentsetting.
SENSORS POS: XXXXX Entry
Default
L243
Temperature range -50..50°C
K277 Temperature range -50..50°C
5K3A1 Temperature range 0..100°C
Menu6-3Cooling
COOLING POS: XXXXX Entry
Default
Min. On Time XX K Minimum cooling ON time 0..15
2 m
Min. Off Time XX m Minimum cooling OFF time 0..15
2 m
Cont Cool Mon. xx m Duration of forced interruption of cooling in
continuous running
--, 0..15
---m
Emergency Op. xx m In failure of required sensors, the solenoid valve is
actuated to adjust to the set opening in %.
0..100
100%
Menu6-4Language
LANGUAGE POS: XXXXX Entry
Default
Deutsch D
English GB
Francais F
Espagnol E
Finnish FIN
Türkce TR
Cesky CZ