Titanium Interfaces User Guide
pll_rule_input_freq (error)
Message Input Frequency <float> MHz (after pre-divider) is out of range. Min=<float>MHz
Max=<float>MHz
To fix Assign the reference clock frequency to a value within the specified range.
pll_rule_input_freq_limit (error)
Message Input Frequency <float> MHz is out of range. Min=<float>MHz Max=<float>MHz
To fix Assign the right reference clock frequency.
pll_rule_inst_name (error)
Message Instance name is empty
Valid characters are alphanumeric characters with dash and underscore only
To fix Specify a valid instance name.
pll_rule_mipi_tx_clock (error)
Message PLL output clock <name> is not allowed to connect to MIPI TX Lane Serial and Parallel clocks
at the same time
To fix You cannot use the slow clock for one MIPI TX lane as the fast clock for a different MIPI TX
lane.
pll_rule_multiplier (error)
Message Multiplier is out of range. Min=<int> Max=<int>
To fix The multiplier frequency needs to be within the range specified. Adjust the parameters to
meet that requirement.
pll_rule_output_clock (error)
Message At least one output clock must be configured
To fix Configure at least one PLL output clock and specify the output clock pin name.
Message Output clock count is out of range. Min=<int>Max=<int>
To fix You have specified the wrong number of output clocks (too many or none).
pll_rule_output_divider (error)
Message Output divider for <clock name> is invalid. Valid values are between 1-128
To fix Choose a value between 1 and 128.
pll_rule_output_freq (error)
Message Output frequency <float>MHz is out of range. Min=<float>MHz Max=<float>MHz
To fix The output frequency needs to be within the range specified. Adjust the parameters to meet
that requirement.
www.efinixinc.com 128