Promag 53 PROFIBUS DP/PA Technical data
Endress+Hauser 163
Optional
High-temperature version (HT): –20 to +180 °C (–4 to +356 °F) for PFA (DN 25 to 200 /
1to8")
A0002660
Fig. 76: Promag P compact version (with PFA or PTFE lining)
TA = ambient temperature; TF = fluid temperature; HT = high-temperature version with insulation
m
= Light gray area
temperature range from –10 to –40 °C (–14 to –40 °F) applies only to stainless steel flanges
n
= Diagonally hatched area
foam lining (HE) + degree of protection IP68 = fluid temperature max. 130°C (266 °F)
a0002671
Fig. 77: Remote versions (with PFA or PTFE lining)
TA = ambient temperature; TF = fluid temperature; HT = high-temperature version with insulation
m
= Light gray area
temperature range from –10 to –40 °C (–14 to –40 °F) applies only to stainless steel flanges
n
= Diagonally hatched area
foam lining (HE) + degree of protection IP68 = fluid temperature max. 130°C (266 °F)
Promag W
• 0 to +80 °C (+32 to +176 °F) for hard rubber (DN 65 to 2000 / 2½ to 80")
• –20 to +50 °C (–4 to +122 °F) for polyurethane (DN 25 to 1200 / 1 to 48")
PTFE
HT
m
PFA
n
0
0
0
0
-20-40
-40
20
20
40
100
60
140
[°F] [°C]
T
A
40 60 80
T
F
100
100
120 140 160
200 300
180 [°C]
360 [°F]
-20
-40
-40
HT
PTFE
m
n
PFA
0
0
0
0
-20-40
-40
20
20
40
100
60
140
[°F] [°C]
T
A
40 60 80
T
F
100
100
120 140 160
200 300
180 [°C]
360 [°F]
-20
-40
-40