Technical data Promag 53 PROFIBUS DP/PA
180 Endress+Hauser
Fitted electrodes
Promag E/L
• 2 measuring electrodes for signal detection
• 1 EPD electrode for empty pipe detection
• 1 reference electrode for potential equalization
Promag H
• 2 measuring electrodes for signal detection
• 1 EPD electrode for empty pipe detection, not for DN 2 to 15 (1/12" to ½")
Promag P
Available as standard:
• 2 measuring electrodes for signal detection
• 1 EPD electrode for empty pipe detection
• 1 Reference electrode for potential equalization
Optionally available:
• Platinum measuring electrodes only
Promag W
Available as standard:
• 2 measuring electrodes for signal detection
• 1 EPD electrode for empty pipe detection
• 1 Reference electrode for potential equalization
Optionally available:
• Exchangeable measuring electrodes for DN 350 to 2000 (14 to 78")
Process connection
Promag E
Flange connections:
• EN 1092-1 (DIN 2501)
–DN 300 (12") = form A
–DN 350 (14") = flat face
– DN 65 PN 16 and DN 600 PN 16 only as per EN 1092-1
•ASME
•JIS
Promag H
With O-ring:
• Weld nipple DIN (EN), ISO 1127, ODT/SMS
•Flange EN (DIN), ASME, JIS
• Flange made of PVDF EN (DIN), ASME, JIS
•External thread
• Internal thread
• Hose connection
•PVC adhesive fitting
With molded seal:
• Weld nipple DIN 11850, ODT/SMS
• Clamp ISO 2852, DIN 32676, L14 AM7
• Coupling DIN 11851, DIN 11864-1, ISO 2853, SMS 1145
• Flange DIN 11864-2