Operation Promag 53 PROFIBUS DP/PA
70 Endress+Hauser
5.2.5 Controlling the batching processes using the local display
Filling processes can be carried out directly by means of the local display with the aid of the
optional "(Batching)" software package (F-CHIP, accessories → 128). Therefore, the device
can be fully deployed in the field as a "batch controller."
Procedure:
1. Configure all the required batching functions and assign the lower display info line (=
BATCHING KEYS) using the "Batch" Quick Setup menu (→ 90) or use the function
matrix ( → 71).
The following "softkeys" then appear on the bottom line of the local display → 45:
– START = left display key ()
– PRESET = middle display key ()
– MATRIX = right display key ()
2. Press the "PRESET ()" key. Various batching process functions requiring configuration
will now appear on the display:
3. After exiting the PRESET menu, you can now start the batching process by pressing
"START ()". New softkeys (STOP/HOLD or GO ON) now appear on the display. You can
use these to interrupt, continue or stop the batching process at any time. → 45
STOP () Stops batching process
HOLD () Interrupts batching process (softkey changes to "GO ON")
GO ON () Continues batching process (softkey changes to "HOLD")
After the batch quantity is reached, the "START" or "PRESET" softkeys reappear on the
display.
a0004386
Fig. 45: Controlling batching processes using the local display (softkeys)
"PRESET" Initial settings for the batching process
No. Function Settings
7200 BATCH SELECTOR OS Selection of the batching fluid (BATCH #1 to 6)
7203 BATCHING QUANTITY If the "ACCESS CUSTOMER" option was selected for the "PRESET
batch quantity" prompt in the "Batching" Quick Setup, the batching
quantity can be altered via the local display. If the "LOCKED"
option was selected, the batching quantity can only be read and
cannot be altered until the private code has been entered.
7265 RESET TOTAL QUANTITY/
TOTALIZER
Resets the batching quantity counter or the total batching
quantity to "0".
STOP GO ON MATRIX
+2.5 l
0.0 l
+
-
+2.5 l
0.0 l
START
PRESET MATRIX
STOP HOLD MATRIX
E