Promag 53 PROFIBUS DP/PA Technical data
Endress+Hauser 167
Promag P (Measuring tube lining: PTFE)
Promag W
Limiting flow
Further information can be found in the "Nominal diameter and flow rate" → 17 section
Pressure loss
• No pressure loss if the sensor is installed in piping with the same nominal diameter (for
Promag H only from DN8).
• Pressure losses for configurations incorporating adapters according to DIN EN 545 →
16.
2008"0*0000
* No value can be quoted.
Nominal diameter Resistance of measuring tube lining to partial vacuum: limit values for
absolute pressure [mbar] ([psi]) at various fluid temperatures
[mm] [inch]
25 °C 80° C 100 °C 130 °C 150 °C 180 °C
77 °F 176° F 212 °F 266 °F 302 °F 356 °F
[mbar] [psi] [mbar] [psi] [mbar] [psi]
15½"000001001,45––
251"000001001,45––
32 - 0 0 0 0 0 100 1,45 – –
40 1 ½" 0 0 0 0 0 100 1,45 – –
502"000001001,45––
65 - 0 0 * 40 0,58 130 1,89 – –
80 3" 0 0 * 40 0,58 130 1,89 – –
100 4" 0 0 * 135 1,96 170 2,47 – –
125 - 135 1,96 * 240 3,48 385 5,58 – –
150 6" 135 1,96 * 240 3,48 385 5,58 – –
200 8" 200 2,90 * 290 4,21 410 5,95 – –
250 10" 330 4,79 * 400 5,80 530 7,69 – –
300 12" 400 5,80 * 500 7,25 630 9,14 – –
350 14" 470 6,82 * 600 8,70 730 10,59 – –
400 16" 540 7,83 * 670 9,72 800 11,60 – –
450 18" Partial vacuum is impermissible
500 20"
600 24"
* No value can be quoted.
Nominal diameter Measuring
tube lining
Resistance of measuring tube lining to partial vacuum: limit values
for absolute pressure [mbar] ([psi]) at various fluid temperatures
[mm] [inch]
25 °C 50 °C 80° C 100 °C 130 °C 150 °C 180 °C
77 °F 122 °F 176° F 212 °F 266 °F 302 °F 356 °F
25 to 1200 1 to 48" Polyurethane 0 0 - - - - -
65 to 2000 3 to 78" Hard rubber 0 0 0 - - - -
Nominal diameter Resistance of measuring tube lining to partial vacuum: limit values for
absolute pressure [mbar] ([psi]) at various fluid temperatures
[mm] [inch]
25 °C 80° C 100 °C 130 °C 150 °C 180 °C
77 °F 176° F 212 °F 266 °F 302 °F 356 °F