EasyManua.ls Logo

Endress+Hauser Proline Prosonic Flow P 500 - Page 111

Endress+Hauser Proline Prosonic Flow P 500
224 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Proline Prosonic Flow P 500 HART Commissioning
Endress+Hauser 111
Parameter overview with brief description
Parameter Prerequisite Description Selection / User
interface / User
entry
Factory setting
Operating mode Define the output as a pulse,
frequency or switch output.
Pulse
Frequency
Switch
Pulse
Terminal number Shows the terminal numbers
used by the PFS output
module.
Not used
24-25 (I/O 2)
22-23 (I/O 3)
Signal mode Select the signal mode for the
PFS output.
Passive
Active
*
Passive NE
Passive
Assign pulse output The Pulse option is selected in
Operating mode parameter.
Select process variable for
pulse output.
Off
Volume flow
Mass flow
GSV flow
*
NSV flow
*
S&W volume flow
*
Product 1 volume
flow
*
Product 2 volume
flow
*
Product 3 volume
flow
*
Product 4 volume
flow
*
Product 5 volume
flow
*
Product 1 mass
flow
*
Product 2 mass
flow
*
Product 3 mass
flow
*
Product 4 mass
flow
*
Product 5 mass
flow
*
Product 1 NSV
flow
*
Product 2 NSV
flow
*
Product 3 NSV
flow
*
Product 4 NSV
flow
*
Product 5 NSV
flow
*
Off
Pulse scaling The Pulse option is selected in
the Operating mode
parameter (→  110) and a
process variable is selected in
the Assign pulse output
parameter (→  111).
Enter quantity for measured
value at which a pulse is
output.
Positive floating
point number
Depends on country
and nominal
diameter
Pulse width The Pulse option is selected in
the Operating mode
parameter (→  110) and a
process variable is selected in
the Assign pulse output
parameter (→  111).
Define time width of the
output pulse.
0.05 to 2 000 ms 100 ms

Table of Contents

Other manuals for Endress+Hauser Proline Prosonic Flow P 500

Related product manuals