Technical data Proline Prosonic Flow P 500 HART
208 Endress+Hauser
Cable entries and adapters Material
• Adapter for cable entry with female thread G ½"
• Adapter for cable entry with female thread NPT ½"
Only available for certain device versions:
Order code for "Transmitter housing":
Option A "Aluminum, coated"
Nickel-plated brass
• Adapter for cable entry with female thread G ½"
• Adapter for cable entry with female thread NPT ½"
Only available for certain device versions:
Order code for "Transmitter housing":
Option L "Cast, stainless"
Stainless steel, 1.4404 (316L)
Sensor cables
UV rays can impair the cable outer sheath. Protect the cable from exposure to sun as
much as possible.
Sensor cable for sensor - Proline 500 transmitter
DN 15 to 65 (½ to 2½"):
Sensor cable: TPE
6)
• Cable sheath: TPE
• Cable plug: stainless steel 1.4301 (304), 1.4404 (316L), nickel-plated brass
DN 50 to 4000 (2 to 160"):
• Sensor cable, TPE halogen-free
• Cable sheath: TPE halogen-free
• Cable connector: nickel-plated brass
• PTFE sensor cable
6)
• Cable sheath: PTFE
• Cable plug: stainless steel 1.4301 (304), 1.4404 (316L)
Ultrasonic transducer
• Holder: stainless steel 1.4301 (304), 1.4404 (316L)
• Housing: stainless steel 1.4301 (304), 1.4404 (316L)
• Strapping bands/bracket: stainless steel 1.4301 (304), 1.4404 (316L)
• Contact surfaces: chemically stable plastic
Coupling pads
• –40 to +100 °C (–40 to +212 °F): silicon-based thermal pad H48.2 (0.5 mm (0.02 in))
• –40 to +170 °C (–40 to +338 °F): VMQ-silicone-rubber (vinyl methyl silicone)
(0.5 mm (0.02 in))
Coupling foil
• 150 to 220 °C (302 to 428 °F): tin
• 210 to 370 °C (410 to 698 °F): zinc
• 350 to 550 °C (662 to 1 022 °F): aluminum
Coupling paste
Coupling grease
6) Also available in optional armored version (316L)