88
Chapter3 Handling
GS1 DataBar Expanded
‘()’ are used as delimiters for the application identifiers. (printed as the HRI character, but not encoded.)
Be sure to include all the application identifiers in the data.
If the first data is “01” when an application identifier, left and right parentheses, and * are excluded, the 14th
digit counted from the digit next to “01” is used as the check digit. If the data is incorrect, an error will occur.
If the number of digits after “01” is less than 14, a check digit is not added.
(Unlike GS1-128, a symbol “*” cannot be used for automatic calculation and addition of a check digit. If “*” is
added in the data, it will be ignored and the subsequent data is shifted by one digit.)
Specify a special character as described below.
Control character ASCII HRI character
FNC1 {1 Not printed
Beginning parenthesis for an application
identifier
( ( is printed.
Closing parenthesis for an application iden-
tifier
) ) is printed.
'*' {* Error
Skipped character * Not printed
'{' {{ { is printed.