3025SW Master Control Switching & Channel Branding
Page 94 Revision 1.0
The GPO script can be created using a text editor (e.g. Notepad) and should have no file extension.
The naming of the GPO script should be the following format:
gpo_config_script
Each GPO can only be configured to trigger (become active) based on any media being on-air or
specific named media being on-air.
Here is an example of what the content of a gpo script that specifies that GPO 2 will trigger when any
media is on-air and GPO 3 will trigger when a media named “ETV_1” is on-air. GPOs 2 and 3 in the
GPI/O tab would need to be configured for MG Script.
obj gpo_config("1")
{
gpo_act="logo_status"
}
obj gpo_config("2")
{
gpo_act="specific_logo_status"
media_name="EVTV_1"
}
The GPOs are specified in the gpo script zero based. So, a gpo script that will trigger all 16 GPOs
when any media is on-air would look like this (all GPOs in the GPI/O tab would need to be
configured for MG Script for this to work):
obj gpo_config("0")
{
gpo_act="logo_status"
}
obj gpo_config("1")
{
gpo_act="logo_status"
}
obj gpo_config("2")
{
gpo_act="logo_status"
}
obj gpo_config("3")
{
gpo_act="logo_status"
}
obj gpo_config("4")
{
gpo_act="logo_status"
}
obj gpo_config("5")
{
gpo_act="logo_status"
}
obj gpo_config("6")
{

Table of Contents