3025SW Master Control Switching & Channel Branding
Revision 1.0 Page 77
#qlink2.warning syslog,console
#com1.notice syslog,console
#com2.info syslog,console
#com3.debug syslog,console
#com4.* syslog,console
#com5.* syslog,console
#com6.* syslog,console
#asrun.* syslog,console
#tsnsorsoft.* syslog,console
#eas.* syslog,console
#m2100_server.* syslog,console
#nas.* syslog,console
Notice that every line in the syslog.conf file has a “#” characters at the beginning of the line. This
character tells the 3025SW to ignore this line.
Each line in the syslog file has a port/operation, a logging level and a destination. For example,
“#com4.* syslog,console”
Configure the 3025SW channel to log all logging levels for serial port 4 to both the serial console
(console) and the syslog (IP). The serial logging (console) is logged to the 3025SW debug serial port
(J11) which can be found on the front edge of the board.
The possible port/operation options are as follows:
ftp file transfer protocol operations.
netlinkEthernet based control panels connects/disconnects.
netcmdcommands received from Ethernet based control panels, i.e. manual operations.
com1logging for serial port 1.
com2logging for serial port 2.
com3logging for serial port 3.
com4logging for serial port 4.
com5logging for serial port 5.
com6logging for serial port 6.
qlink2logging for the Evertz Router Upstream Control port.
asrunthis is needed for debugging complex issues and enables logging of custom logging that needs
to specifically enabled on the 3025SW channel.
tsnsorsoft this is for logging communications between the 3025SW and the temperature probe (if
fitted).
eas this is for logging communications between the 3025SW and eas equipment (IP or serial).
M2100_serverthis is for logging M2100 serial communications between the 3025SW and Overture
RT.
nasthis is for logging network attached storage connection related events.
The supported logging levels are as follows. The higher the level of logging, the more data that will be
logged. “.*” specifies all possible logging data for the port/operation…
emergLOWEST LOGGING LEVEL
alert
crit
err