4. Commissioning positioning systems
4−24
Festo P.BE−SPC200−WIN−PISA−CD−EN en 0901d
Cylinder length/
Cylinder swivel angle
The length or swivel range of the drive (see type plate).
Permitted: 50 ... 10000 [mm] or [°]
Cylinder diameter The diameter of the drive used (see type plate).
Measuring system
design
Design of the measuring system. Select here the type of
measurement system used from the list:
potentiometer
temposonics (digital
measuring system)
encoder
(the measuring system length is defined fixed with the
selection Encoder")
Measuring system length/
Measuring system swivel
angle
The length or swivel range of the measuring system used
(see type plate).
Permitted: 50 ... 10000 [mm] or [°]
Measuring system
parameter
This parameter is only displayed in the Encoder" setting of
the Measuring system
design" field. The setting is reserved
for later developments.
Valve type Identification of the valve. Here select the type of valve used
from the list:
MPYE−5−M5−010B
MPYE−5−1/8−LF−010B
MPYE−5−1/8−HF−010B
MPYE−5−1/4−010B
MPYE−5−3/8−010B