4. Commissioning positioning systems
4−40
Festo P.BE−SPC200−WIN−PISA−CD−EN en 0901d
4.3.5 Loading the project into the SPC200
Download the whole project to the SPC200 to make all the
settings selected in the project effective in the SPC200.
The project must be compiled before it can be downloaded to
the SPC200.
To compile the whole project:
1. Save the project using [Save project] in the [File] menu.
2. Select [Project] from the [Compile] menu
or click on the
Compile project" button.
3. The progress of compilation is shown in the Compile"
window. Wait until the process is complete.
4. Click OK" in the Compile" window to confirm the com
pleted check and compilation.
Check the message window. If errors are displayed, these can
be remedied and compilation repeated.
WinPISA will
open the associated program and jump to the
appropriate program line when you double−click on a mess
age in the message window (see section 4.9).
Please note
A system reset automatically occurs with the following
actions:
Project download with fieldbus module
Changing the hardware configuration,
Only for fieldbus:
Changing the start program, changing fieldbus configur
ation.
When the system is reset, the axis status flag REF (refer
ence set) is cleared and has to be referenced again; see
G74.