127
EN-US
Description The inverter stops feeding power into the grid, the display
shows a critical error via a red Operating Status LED.
Remedy If status code persists: Contact a Fronius-trained service tech-
nician
452
Communication between ‘Guard’ and the digital signal processor (DSP) has been inter-
rupted
Description The inverter stops feeding power into the grid, the display
shows a critical error via a red Operating Status LED.
Remedy If status code persists: Contact a Fronius-trained service tech-
nician
453
Error in grid voltage recording
Description The inverter stops feeding power into the grid, the display
shows a critical error via a red Operating Status LED.
Remedy If status code persists: Contact a Fronius-trained service tech-
nician
454
Error in grid frequency recording
Description The inverter stops feeding power into the grid, the display
shows a critical error via a red Operating Status LED.
Remedy If status code persists: Contact a Fronius-trained service tech-
nician
455
Reference power source for AC measurement is operating outside of tolerances
Description The inverter stops feeding power into the grid, the display
shows a critical error via a red Operating Status LED.
Remedy If status code persists: Contact a Fronius-trained service tech-
nician
456
Error during anti-islanding test
Description The inverter stops feeding power into the grid, the display
shows a critical error via a red Operating Status LED.
Remedy If status code persists: Contact a Fronius-trained service tech-
nician
457
Grid relay stuck
Description The inverter stops feeding power into the grid, the display
shows a critical error via a red Operating Status LED.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius IG Plus A 3.0-1 UNI and is the answer not in the manual?

Fronius IG Plus A 3.0-1 UNI Specifications

General IconGeneral
AC nominal output3000 W
Max. apparent AC power3000 VA
Max. output current13 A
AC grid frequency50 / 60 Hz
THD<3%
Max. DC voltage500 V
Number of MPP trackers1
AC voltage range183 V - 264 V
DC input voltage range150 - 450 V
CoolingConvection