Inserting Option Cards
Suitable option
cards
There are several options and system upgrades available for the inverter, e.g.:
- Datalogger and modem interface, Ethernet/Internet connection (for using a PC to re-
cord and manage data from your photovoltaic system)
- Various large displays (Fronius Public Display)
- Fronius Personal Display
- Fronius Datamanager
- Fronius Modbus Card
System upgrades are available as plug-in cards and as external boxes. The Fronius IG
Plus A is designed for one option card.
Safety
Opening the in-
verter
When adding option cards to the inverter, please follow all inverter safety instructions and
information before opening the inverter.
1 2
WARNING! An electric shock can be fatal. Danger from grid voltage and DC volt-
age from solar modules.
- The connection area should only be opened by a licensed electrician.
- Never work with live wires! Prior to all connection work, make sure that the
AC and DC wires are not charged.
- All electrical installations must be carried out in accordance with the National
Electrical Code, ANSI/NFPA 70, and any other codes and regulations appli-
cable to the installation site.
- For installations in Canada, the installations must be done in accordance with
applicable Canadian standards.
WARNING! An electric shock can be fatal. Danger from residual voltage from ca-
pacitors.
You must wait until the capacitors have discharged. Discharge takes 5 minutes.
NOTE! Follow general ESD precautions when handling option cards.
off
on
1
2
OFF
AC
OFF
ON
1
1
4
2
3
2

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius IG Plus A 3.0-1 UNI and is the answer not in the manual?

Fronius IG Plus A 3.0-1 UNI Specifications

General IconGeneral
AC nominal output3000 W
Max. apparent AC power3000 VA
Max. output current13 A
AC grid frequency50 / 60 Hz
THD<3%
Max. DC voltage500 V
Number of MPP trackers1
AC voltage range183 V - 264 V
DC input voltage range150 - 450 V
CoolingConvection